INSTALLATION INSTRUCTIONS:
step1: Drill 3/4" diameter by 7/8 deep hole for magnetic contact
step2:Connect contact leads to security system loop and test for continuity
step3: Insert contact and wires into mounting hole and secure with#4 flathead screws(provided). if gap is excessive,add spacer(s) as needed to move contact out from frame
NOTE: In order to comply with UL installations,the contact shpuld not be used on outward opening exterior door. |